High-pressure blower unit with backward-curved impeller

PRODUCT APPLICATIONS
Widely used for exhaust, smoke extraction, or ventilation in various settings; also suitable for industrial dust purification, coating equipment systems, and indoor ventilation for large buildings.
PERFORMANCE
The high-efficiency centrifugal impeller features an aerodynamic design with streamlined blades, ensuring low airflow noise.
The casing is designed with a spacious, unobstructed internal airflow path at the inlet, delivering higher airflow rates compared to similar models from other brands.
The unit is dynamically balanced to G2.5 precision, resulting in minimal vibration and low mechanical noise.
The internal single-frame structure minimizes air resistance and reduces airflow noise.
The casing and exterior panels are constructed from high-quality, oxidation- and corrosion-resistant materials, ensuring durability against wind, sun, and rain.
The main shaft is made of high-quality carbon steel, precision-ground and heat-treated (quenched and tempered) for superior strength.
Components—including the motor, bearings, pulleys, and belts—are sourced from renowned, high-quality brands, further enhancing the unit’s durability and service life.
The pulley utilizes a locking-sleeve connection, facilitating easy installation, removal, and maintenance.

Description

PARAMETER

Specifications and Model Motor Power (kW) Rotational speed (r/min) External static pressure (Pa) Airflow (m³/h) Noise dB(A) Air inlet (mm) Air outlet (mm) Enclosure dimensions (mm) Overall dimensions (mm)
4.5 4 1957 450~1020 6500~12000 76 990*850 570*570 1150*950*950 1290*990*1270
5.5 2109 1280~560 7300~13500 79
7.5 2448 1430~630 7700~14200 81
11 2607 1810~800 8700~16000 83
5 5.5 1861 1130~570 8500~16000 81 1160*950 640*640 1320*1000*1050 1450*1040*1400
7.5 2067 1400~700 9400~17800 84
11 2290 1700~860 10500~19600 86 1450*1040*1530
15 2582 2180~1090 11800~22200 88
5.6 7.5 1636 1220~600 11100~21300 84 1300*1000 710*710 1500*1100*1105 1640*1140*1585
11 1825 1520~750 12300~23800 86
15 2089 2000~980 14200~27300 89
18.5 2344 2500~1230 15900~30600 92
22 2449 2730~1340 16600~32000 93
6.3 7.5 1364 1060~540 13700~25100 83 1300*1160 800*800 1500*1250*1260 1650*1290*1740
11 1551 1370~700 15600~28600 86
15 1720 1690~860 17300~31700 89
18.5 1934 2160~1100 19600~35900 91
22 2040 2380~1210 20600~37600 92
30 2162 2720~1390 22000~40200 94
7.1 11 1168 1040~580 16700~40000 85 1550*1290 900*900 1750*1350*1390 1880*1390*1870
15 1314 1310~730 18800~45000 87
18.5 1470 1590~880 20600~50000 89
22 1547 1820~1010 22100~53300 91
30 1633 2060~1150 23500~56800 92

MAINTENANCE
Exercise care to prevent impacts or collisions during transport and handling; ensure protection against water, moisture, and vibration during storage.
Before use, verify that the supply voltage matches the specifications on the nameplate (allowable voltage tolerance: ±10%) and ensure the motor is properly grounded. Prior to powering on, check that the impeller rotates freely; resolve any issues immediately.
Under normal conditions, the unit should start within a few seconds of being powered on. If it fails to start or runs sluggishly, disconnect the power immediately to inspect and rectify the fault before further use.